Customer: Waste Disposal Provider
Need/Application: Needed to heat a 6,000 gallon tank of glycerin.
Solution: Provided a skid unit with a Blackmer Gear (formerly EnviroGear) pump to recirculate glycerin from the tank into both the Standard Plate and frame heat exchanger. The skid also has a electric heater to heat the water with a Xylem pump to recirculate the water from the day tank into the heater and then through the heat exchanger. We built the electric panel to our specifications that included temperature controls to start/stop the pumps when desired and then mounted it on a retaining wall 3 feet off the floor per request.